KSTAR UBR60L Memopower Plus RTII Online Series Rack Mount UPS - 6000VA

R14,189.00
SKU
KSUBR60L
DSP technology guarantees high reliability True double-conversion Rack-mounted and floor-standing tower can be convertible
Confirm Availability
In stock
Safe & Secure Shopping
Satisfaction Guaranteed

Manufacturer's Website

 

Description

The KSTAR UBR60L Memopower Plus RTII Online Series Rack Mount UPS - 6000VA is a single-phase uninterruptible power supply with double-conversion technology and DSP control.

It delivers a rated power of 6-10kva and can be used in both tower and rack configurations. The patented mini LCD screen can be rotated according to a different type of deployment.

 

Features

  • True double-conversion
  • Rack-mounted and floor-standing tower can be convertible
  • Patented Minic LCD of which content can be rotated according to the type of deployment
  • DSP technology guarantees high reliability
  • N+X parallel redundancy
  • Selectable quantity of battery for each group:16/18/20 pieces
  • Adjustable charging current via LCD
  • 3-stage charging design optimizes battery performance
  • ECO mode operation for energy saving
  • Self-diagnosis at startup
  • Emergency power off function(EPO)
  • Maintenance bypass is convenient for maintenance
  • Generator compatible
  • PDU is convenient for connecting load
  • Communications:RS-232,USB,SNMP card (Optional), Relay card (Optional)
  • Cold start

 

Specifications

Model UBR60L
Capacity 6000VA/5400Watts
Input
Nominal Voltage 220/230/240Vac (L+N+PE)
Operating Voltage Range 120Vac-276Vac
Operating Frequency Range 50Hz45 to 55Hz60Hz54 to 66Hz
Power Factor 0.99
Bypass Voltage Range Max.voltage: 220V+25% (Optional +10%,+15%,+20% ), 230V+20%(Optional +10%,+15%), 240V+15% (Optional +10% ), Min. voltage: -45% (Optional -20%,-30%)
ECO Range Same as Bypass
Harmonic Distortion (THDi) 5%(100% non-linear load)
Output
Output Voltage 220/230/240Vac
Power Factor 0.9
Voltage Regulation 1%
Frequency
Line Mode 1%/2%/4%/5%/10% of the rated frequency(Optional)
Battery Mode (50/600.1)Hz
Crest Factor 3:1
Harmonic Distortion THDv 2% with linear load, 5% with non-linear load
Waveform Pure Sinewave
Transfer Time Utility to Battery: 0ms Utility to Bypass: 0ms
Efficiency
Efficiency Up to 94%
Battery
Battery Voltage Optional Voltage: 96/108/120Vdc
Typical Recharge Time 6-8 hours (To 90% capacity)
Charging Current Maximum current 10A
Protection
Overload Line Mode Load125%: last 5min150%: last 1min150% 200ms turn to bypass mode
Overload Bypass Mode 40A (Input breaker)
Short Circuit Hold Whole System
Overheat Line Mode: Switch to Bypass Backup Mode: Shut down UPS immediately
Battery Low Alarm and Switch off
Indicators
Audible and Visual Alarms Line Failure, Battery Low, Overload, System Fault
Status LED and LCD Display Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Reading On The LCD Display Input/Output Voltage, Input/Output Frequency, Load Level, Battery Level, Inner Temperature & Remaining Battery Backup Time
Management
Communication Interface RS232,USB, Parallel Port, SNMP card (Optional), Relay card (Optional)
Environment
Operating Temperature 0 degree Celsius to 40 degree Celsius
Storage Temperature -25 degree Celsius to 55 degree Celsius
Humidity Range 0 to 95% (Non-condensing)
Altitude < 1500m
Noise Level <55dB
Physical
Dimension 443mm x 580mm x 131mm (W x D x H)
Net Weight 19
Standards
Noise Suppression Complies with EN62040-2
Safety IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8